Adjust the water PH to 10.5~12, and temperature to
35~45℃,
then membrane contactor can used for
deammonia, product water ammonia content can be decreased to 0.5mg/L.
membrane contactor is a kind of special hydrophobic
hollow fiber array made of polymer material. Then the array is spiral-wounded
onto a water distribution tube, and then the tube is installed into a housing
(at the same time, a baffler is formulated inside the housing).
Hollow fiber → Knitted fiber (under
microscope) → Knitted fiber (naked
eyes) → End surface
Structure
of membrane contactor:
Features
of membrane contactor:
1) Hollow
fibers are knitted into an array, so that a certain space can be kept between
these fibers. In this way, thousands of fibers are connected as a whole array
which can resist strong water flow and will not break. Besides, the mass
transfer efficiency can be improved in the array structure.
2) High fiber
density makes it possible of ultimate gas removal from water;
3) Central
tube water distribution + Middle baffler structure, change the water flow
direction to flush vertically towards hollow fibers, which can improve the mass
transfer efficiency between shell side and lumen side.
Working
principle of deammonium membrane
NH4+ has the following equilibrium in water:
NH4++OH- ←→ NH3+H2O
In typical operation, wastewater flows in the shell
side of membrane, while acid adsorption solution flows in the lumen side of
membrane.
With the increase of temperature and PH in water, the
equilibrium favors the formation of free NH3 gas. NH3 gas can
permeate through the micro pores from shell side to lumen side, then act with
acid:
2NH3 + H2SO4 → (NH4)2SO4
Keep the water PH above 10, and temperature above 35℃ (below 45℃), then the NH4+ in the shell side will be changed to NH3 constantly
and permeate to the lumen side, then be reacted to NH4+. By these reactions,
NH4+ content in wastewater can be decreased to the satisfied level. At the
same time, pure (NH4)2SO4 is generated in the lumen side, which can be
recycled.
Typical
working process of ETN membrane
Remarks: the equipment in dotted line is replaced
by membrane contactor
membrane contactor deammonia system has the
following advantages compared with traditional ammoniua removal technology:
1)
High removal efficiency of ammonia nitrate, NH4+-N can be
decreased to below 1ppm. And the removal efficiency can be accurately fixed
based on practical condition;
2)
NH4+-N stripping and adsorption in one step, to get a
smaller footprint, less than 1/3 of tradition process;
3)
Modular design, easy for transportation and capacity extension;
4)
It offers a closed operation environment, which can ensure no NH3 leakage
and cleaning production.
Specifications
of ETN membrane
Item
Parameters
Model
ETN-6×28
ETN-10×28
Application
Ammonia/ammonium
removal in wastewater
Capacity
0.75~1.5m3/h
2.0~4.0
m3/h
Fiber
material
Polypropylene
Dimensions
Ø6×28
inch
Ø10×28
inch
Liquid/Gas
contactor area
30m2
90m2
Inner/Outer
diameter of fiber
0.4/0.5mm
Housing
material
UPVC
PH
resistance range
1~13
Working
temperature
35~45℃
Max
inlet water pressure
6.0bar
Inlet/outlet
pipe diameter
DN32
DN32
Contact:Tel:+86 592 6514970Skype:18060902001WhatsApp:18060902001WeChat:18060902001TM: guochukejiQQ:1641011431
- Product Details
- Brand :
- Place of Origin : FUJIAN
- FOB Price : On Request
- Minimum Order Quantity : Not Given
- Supply Ability :
- Packaging & Delivery
- Packaging Detail : Not Given
- Delivery Detail : Not Given
Adjust the water PH to 10.5~12, and temperature to 35~45℃, then membrane contactor can used for deammonia, product water ammonia content can be decreased to 0.5mg/L.membrane contactor is a kind of special hydrophobic hollow fiber array made of polymer material. Then the array is spiral-wounded onto a water distribution tube, and then the tube is installed into a housing (at the same time, a baffler is formulated inside the housing). Hollow fiber → Knitted fiber (under microscope) → Knitted fiber (naked eyes) → End surface Structure of membrane contactor: Features of membrane contactor:1) Hollow fibers are knitted into an array, so that a certain space can be kept between these fibers. In this way, thousands of fibers are connected as a whole array which can resist strong water flow and will not break. Besides, the mass transfer efficiency can be improved in the array structure.2) High fiber density makes it possible of ultimate gas removal from water;3) Central tube water distribution + Middle baffler structure, change the water flow direction to flush vertically towards hollow fibers, which can improve the mass transfer efficiency between shell side and lumen side. Working principle of deammonium membraneNH4+ has the following equilibrium in water:NH4++OH- ←→ NH3+H2OIn typical operation, wastewater flows in the shell side of membrane, while acid adsorption solution flows in the lumen side of membrane.With the increase of temperature and PH in water, the equilibrium favors the formation of free NH3 gas. NH3 gas can permeate through the micro pores from shell side to lumen side, then act with acid:2NH3 + H2SO4 → (NH4)2SO4Keep the water PH above 10, and temperature above 35℃ (below 45℃), then the NH4+ in the shell side will be changed to NH3 constantly and permeate to the lumen side, then be reacted to NH4+. By these reactions, NH4+ content in wastewater can be decreased to the satisfied level. At the same time, pure (NH4)2SO4 is generated in the lumen side, which can be recycled.Typical working process of ETN membraneRemarks: the equipment in dotted line is replaced by membrane contactormembrane contactor deammonia system has the following advantages compared with traditional ammoniua removal technology:1) High removal efficiency of ammonia nitrate, NH4+-N can be decreased to below 1ppm. And the removal efficiency can be accurately fixed based on practical condition;2) NH4+-N stripping and adsorption in one step, to get a smaller footprint, less than 1/3 of tradition process;3) Modular design, easy for transportation and capacity extension;4) It offers a closed operation environment, which can ensure no NH3 leakage and cleaning production.Specifications of ETN membraneItemParametersModelETN-6×28ETN-10×28ApplicationAmmonia/ammonium removal in wastewaterCapacity0.75~1.5m3/h2.0~4.0 m3/hFiber materialPolypropyleneDimensionsØ6×28 inchØ10×28 inchLiquid/Gas contactor area30m290m2Inner/Outer diameter of fiber0.4/0.5mmHousing materialUPVCPH resistance range1~13Working temperature35~45℃Max inlet water pressure6.0barInlet/outlet pipe diameterDN32DN32Contact:Tel:+86 592 6514970Skype:18060902001WhatsApp:18060902001WeChat:18060902001TM: guochukejiQQ:1641011431